3 related parameters, 5) tuning-less function type – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual
Page 165

5.2 Tuning-less Function
5-15
5
Adjustments
(5) Tuning-less Function Type
The following table shows the types of tuning-less functions for the version of SERVOPACK software.
∗ The software version number of your SERVOPACK can be checked with Fn012.
5.2.3 Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Software Version*
Tuning-less Type
Meaning
000A or earlier
Tuning-less type 1
−
000B or later
Tuning-less type 2
The level of noise produced is lower than that of Type 1.
Parameter
Meaning
When Enabled Classification
Pn14F
n.
0
Tuning-less type 1
After restart
Tuning
n.
1
[Factory setting]
Tuning-less type 2
Parameter
Name
Mid-execution
changes
Automatic
changes
Pn170
Tuning-less Function Related Switch
No
Yes
Pn401
Force Reference Filter Time Constant
No
Yes
Pn40C
2nd Notch Filter Frequency
No
Yes
Pn40D
2nd Notch Filter Q Value
No
Yes