SMA SC 500CP-10-JP Installation Manual User Manual
Page 85
SMA Solar Technology AG
17 Technical Data
Installation Manual
SCCP-JP-IA-A4-en-12
85
Efficiency (measured without internal power supply)*
* For order option "Noise reduction", the values change (see datasheet).
Max. efficiency / European weighted efficiency /
CEC weighted efficiency
98.6% / 98.4% / 98.5%
Protective Devices
Input-side disconnection point
Motor-driven DC load-break switch
AC disconnection point
AC circuit breaker
DC overvoltage protection
Surge arrester type I
Lightning protection (as per IEC 62305-1)
Lightning protection level III
Grid monitoring
Standard features
Islanding detection
active / passive (optional)
Ground fault monitoring / remote ground fault monitoring
optional / optional
Insulation monitoring
optional
Surge arrester for communication interface /
string-current monitoring
optional / optional
Surge arrester for auxiliary power supply
Surge arrester type I and type II
Protection class (as per IEC 62103) /
overvoltage category (as per IEC 60664-1)
I / III
General Data
Dimensions (width x height x depth)
2,562 mm / 2,272 mm / 956 mm***
Weight***
approx. 1,800 kg
Operating temperature range
− 25°C to +62°C
Noise emission*
* Sound pressure level at a distance of 10 m
61 db(A)***
*** For order option "Noise reduction", the values change (see datasheet).
Max. self-consumption (operation)** /
self-consumption (night)
** Self-consumption at rated operation
1,900 W / < 100 W
External auxiliary supply voltage
230 / 400 V (3/N/PE)
Cooling concept
Opticool
Degree of protection: electronics / connection area
(as per IEC 60529)
IP54 / IP43
Application
In unprotected outdoor environments
Maximum permissible value for relative humidity
(non-condensing)
15% to 95%
Maximum operating altitude above MSL
2,000 m
Fresh air consumption
3,000 m
3