beautypg.com

7 mounting the ventilation plate – SMA SC 500CP-10-JP Installation Manual User Manual

Page 41

background image

SMA Solar Technology AG

8  Installing the Sunny Central

Installation Manual

SCCP-JP-IA-A4-en-12

41

8.6 Replacing the Desiccant Bag in the Inverter Cabinet

Procedure:

1. Open the inverter cabinet.
2. Remove and dispose of the desiccant bags located under the inverter bridge.
3. Remove the foil from the desiccant bag included in the scope of delivery and position it under the inverter bridges.
4. Close the inverter cabinet.

8.7 Mounting the Ventilation Plate

The guide rails for the ventilation plate are located in the floor area of the inverter cabinet.

Procedure:

• Slide the ventilation plate into the guide rails in the inverter cabinet. The ventilation grid in the ventilation plate is

facing the rear panel.

☑ The ventilation plate is flush with the Sunny Central.

✖ The ventilation plate will not go all the way in?

• Grasp the ventilation plate from underneath and press the middle part upwards while sliding it in.

Desiccant bag in the inverter cabinet
The desiccant bag in the inverter cabinet protects the electronic components from moisture. The desiccant bag must

be replaced by a new desiccant bag one day before commissioning.