3 TCH PROBE 416 DATUM CIRCLE CENTER

Q273=+35 ;CENTER 1ST AXIS

Center of the bolt hole circle: X coordinate

Q274=+35 ;CENTER IN 2ND AXIS

Center of the bolt hole circle: Y coordinate

Q262=50 ;NOMINAL DIAMETER

Diameter of the bolt hole circle

Q291=+90 ;ANGLE OF 1ST HOLE

Polar coordinate angle for 1st hole center

1

Q292=+180 ;ANGLE OF 2ND HOLE

Polar coordinate angle for 2nd hole center

2

Q293=+270 ;ANGLE OF 3RD HOLE

Polar coordinate angle for 3rd hole center

3

Q261=+15 ;MEASURING HEIGHT

Coordinate in the touch probe axis in which the measurement is
made

Q260=+10 ;CLEARANCE HEIGHT

Height in the touch probe axis at which the probe can traverse
without collision

Q305=1 ;NO. IN TABLE

Enter center of bolt hole circle (X and Y) in the datum table

Q331=+0 ;DATUM

Q332=+0 ;DATUM

4 CYCL DEF 7.0 DATUM SHIFT

Use Cycle 7 to shift datum to the center of the bolt hole circle

5 CYCL DEF 7.1 #1

6 CALL PGM 35KL7