37

3.1 Measur

ing W

o

rk

piece Misalignment

SET BASIC ROTATION (touch probe cycle 404,
ISO: G404, available as of NC software
280 474-xx)

With touch probe cycle 404 you can set any basic rotation
automatically during program run. This cycle is intended primarily for
resetting a previous basic rotation.

U

U

U

U

Preset value for basic rotation

: Angular value at

which the basic rotation is to be set.

Example: NC blocks

5 TCH PROBE 404 BASIC ROTATION

307=+0 ;PRESET BASIC ROTATION