beautypg.com

Displaying calibration values, 3 calibr a ting a measur ing t ouc h pr obe – HEIDENHAIN TNC 426B (280 472) Touch Probe Cycles User Manual

Page 29

background image

HEIDENHAIN TNC 426, TNC 430

17

2.3 Calibr

a

ting a Measur

ing T

ouc

h Pr

obe

Displaying calibration values

The compensation factors and force ratios are stored in the TNC for
later use whenever the measuring touch probe is needed.

You can display the stored values on the screen by pressing the 3D
CAL soft key.

Storing calibration values in the TOOL.T tool table

If you conduct measurements during program run, the compensation
data for the touch probe can be activated from the tool table via a TOOL
CALL.

To store the calibration data in the TOOL.T tool table, enter the

tool number in the calibration menu (confirm with ENT) and then press
the ENTER R IN TOOL TABLE soft key.

The TNC stores the stylus radius 1 in the R column, and the stylus
radius 2 in the R2 column.

This function is only available if machine parameter 7411
= 1 is set (activate touch probe data with TOOL CALL), and
tool table TOOL.T is active (machine parameter 7260 not
equal to 0).