Example: Determining a basic rotation from two holes

0 BEGIN PGM CYC401 MM

1 TOOL CALL 0 Z

2 TCH PROBE 401 ROT OF 2 HOLES

Q268=+25 ;1ST CENTER 1ST AXIS

Center of the 1st hole: X coordinate

Q269=+15 ;1ST CENTER 2ND AXIS

Center of the 1st hole: Y coordinate

Q270=+80 ;2ND CENTER 1ST AXIS

Center of the 2nd hole: X coordinate

Q271=+35 ;2ND CENTER 2ND AXIS

Center of the 2nd hole: Y coordinate

Q261=-5 ;MEASURING HEIGHT

Coordinate in the touch probe axis in which the measurement is
made

Q260=+20 ;CLEARANCE HEIGHT

Height in the touch probe axis at which the probe can traverse
without collision

Q307=+0 ;PRESET BASIC ROTATION

Angle of the reference line

3 CALL PGM 35K47

Part program call

4 END PGM CYC401 MM

X

Y

25

35

Z

Y

80

15