3 measuring cycle for defining oem cycles, 4 special cy cles – HEIDENHAIN TNC 426B (280 472) Touch Probe Cycles User Manual
Page 117

HEIDENHAIN TNC 426, TNC 430
105
3.4 Special Cy
cles
MEASURING (touch probe cycle 3, available as
of NC software 280 474-xx)
Touch probe cycle 3 measures any position on the workpiece in a
selectable direction. Unlike other measuring cycles, Cycle 3 enables
you to enter the measuring path and feed rate directly. The touch
probe does not retract automatically after determining the measured
value.
1
The touch probe moves from the current position at the entered
feed rate in the defined probing direction. The probing direction
must be defined in the cycle as a polar angle.
2
After the TNC has saved the position, the touch probe stops. The
TNC saves the X, Y, Z coordinates of the probe-tip center in three
successive Q parameters. You define the number of the first
parameter in the cycle.
3
If necessary, you must program the retraction of the touch probe
in a separate traversing block.
U
U
U
U
Parameter number for result
: Enter the number of
the Q parameter to which you want the TNC to assign
the first coordinate (X).
U
U
U
U
Probe axis
: Enter the reference axis of the working
plane (X for tool axis Z, Z for tool axis Y, and Y for tool
axis X), and confirm with ENT.
U
U
U
U
Probing angle
: Angle, measured from the probing
axis, at which the touch probe is to move. Confirm
with ENT.
U
U
U
U
Maximum measuring path
: Enter the maximum
distance from the starting point by which the touch
probe may move. Confirm with ENT.
U
U
U
U
Feed rate
: Enter the measuring feed rate.
U
U
U
U
To end input: press the ENT key
Before programming, note the following:
With function FN17: SYSWRITE ID 990 NR 6 you can set
whether the cycle runs through the probe input X12 or
X13.
With the non-modal function M141 (available as of NC
software No. 280 476-06) you can switch off tool
monitoring in order to be able to retract the tool in a
traversing block. Make sure that you have selected the
correct disengaging direction, otherwise the touch probe
may be damaged.
Example: NC blocks
5 TCH PROBE 3.0 MEASURING
6 TCH PROBE 3.1 Q1
7 TCH PROBE 3.2 X ANGLE: +15
8 TCH PROBE 3.3 DIST +10 F100