91

3.3 A

u

to

matic W

o

rk

piece Measur

ement

U

U

U

U

Measuring axis

Q272: axis in the working plane in

which the measurement is to be made:
1: Reference axis = measuring axis
2: Minor axis = measuring axis

U

U

U

U

Measuring height in the touch probe axis

Q261

(absolute): coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.

U

U

U

U

Setup clearance

Q320 (incremental): additional

distance between measuring point and ball tip. Q320
is added to MP6140.

U

U

U

U

Clearance height

Q260 (absolute): coordinate in the

touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.

U

U

U

U

Nominal length

Q311: nominal value of the length to

be measured.

U

U

U

U

Maximum dimension

Q288: maximum permissible

length.

U

U

U

U

Minimum dimension

Q289: minimum permissible

length

U

U

U

U

Measuring log

Q281: definition of whether the TNC is

to create a measuring log:
0: No measuring log
1: Generate measuring log: with the standard setting
the TNC saves the log file TCHPR426.TXT in the
directory in which your measuring program is also
stored.

U

U

U

U

PGM stop if tolerance error

Q309: definition of

whether in the event of a violation of tolerance limits
the TNC is to interrupt the program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message

U

U

U

U

Tool number for monitoring

Q330: definition of

whether the TNC is to monitor the tool (see “Tool
monitoring” on page 71)
0: Monitoring not active
>0: Tool number in the tool table TOOL.T

Example: NC blocks

5 TCH PROBE 426 MEASURE RIDGE WIDTH

Q263=+50 ;1ST POINT 1ST AXIS

Q264=+25 ;1ST POINT 2ND AXIS

Q265=+50 ;2ND POINT 1ST AXIS

Q266=+85 ;2ND POINT 2ND AXIS

Q272=2 ;MEASURING AXIS

Q261=-5 ;MEASURING HEIGHT

Q320=0 ;SET-UP CLEARANCE

Q260=+20 ;CLEARANCE HEIGHT

Q311=45 ;NOMINAL LENGTH

Q288=45 ;MAXIMUM DIMENSION

Q289=44.95 ;MINIMUM DIMENSION

Q281=1 ;MEASURING LOG

Q309=0 ;PGM-STOP IF ERROR