3 a u to matic w o rk piece measur ement – HEIDENHAIN TNC 426B (280 472) Touch Probe Cycles User Manual
Page 110

98
3 Touch Probe Cycles for Automatic Workpiece Inspection
3.3 A
u
to
matic W
o
rk
piece Measur
ement
U
U
U
U
First measuring point in the 1st axis
Q263
(absolute): coordinate of the first touch point in the
reference axis of the working plane.
U
U
U
U
First measuring point in the 2nd axis
Q264
(absolute): coordinate of the first touch point in the
minor axis of the working plane.
U
U
U
U
First measuring point in the 3rd axis
Q294
(absolute): coordinate of the first touch point in the
touch probe axis.
U
U
U
U
Second measuring point in the 1st axis
Q265
(absolute): coordinate of the second touch point in the
reference axis of the working plane
U
U
U
U
Second measuring point in the 2nd axis
Q266
(absolute): coordinate of the second touch point in the
minor axis of the working plane
U
U
U
U
Second measuring point in the 3rd axis
Q295
(absolute): coordinate of the second touch point in the
touch probe axis.
U
U
U
U
3rd measuring point in 1st axis
Q296 (absolute):
coordinate of the third touch point in the reference
axis of the working plane.
U
U
U
U
3rd measuring point in 2nd axis
Q297 (absolute):
coordinate of the third touch point in the minor axis of
the working plane.
U
U
U
U
Third measuring point in the 3rd axis
Q298
(absolute): coordinate of the third touch point in the
touch probe axis.
U
U
U
U
Setup clearance
Q320 (incremental): additional
distance between measuring point and ball tip. Q320
is added to MP6140.
U
U
U
U
Clearance height
Q260 (absolute): coordinate in the
touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.
U
U
U
U
Measuring log
Q281: definition of whether the TNC is
to create a measuring log:
0: No measuring log
1: Generate measuring log: with the standard setting
the TNC saves the log file TCHPR431.TXT in the
directory in which your measuring program is also
stored.
Example: NC blocks
5 TCH PROBE 431 MEASURE PLANE
Q263=+20 ;1ST POINT 1ST AXIS
Q264=+20 ;1ST POINT 2ND AXIS
Q294=-10 ;1ST POINT 3RD AXIS
Q265=+50 ;2ND POINT 1ST AXIS
Q266=+80 ;2ND POINT 2ND AXIS
Q295=+0 ;2ND POINT 3RD AXIS
Q296=+90 ;3RD POINT 1ST AXIS
Q297=+35 ;3RD POINT 2ND AXIS
Q298=+12 ;3RD POINT 3RD AXIS
Q320=0 ;SET-UP CLEARANCE
Q260=+5 ;CLEARANCE HEIGHT
Q281=1 ;MEASURING LOG