beautypg.com

3 a u to matic w o rk piece measur ement – HEIDENHAIN TNC 426B (280 472) Touch Probe Cycles User Manual

Page 107

background image

HEIDENHAIN TNC 426, TNC 430

95

3.3 A

u

to

matic W

o

rk

piece Measur

ement

U

U

U

U

Center of 1st axis

Q273 (absolute): bolt hole circle

center (nominal value) in the reference axis of the
working plane.

U

U

U

U

Center in 2nd axis

Q274 (absolute): bolt hole circle

center (nominal value) in the minor axis of the working
plane.

U

U

U

U

Nominal diameter

Q262: enter the bolt hole circle

diameter.

U

U

U

U

Angle of 1st hole

Q291 (absolute): polar coordinate

angle of the first hole center in the working plane.

U

U

U

U

Angle of 2nd hole

Q292 (absolute): polar coordinate

angle of the second hole center in the working plane.

U

U

U

U

Angle of 3rd hole

Q293 (absolute): polar coordinate

angle of the third hole center in the working plane.

U

U

U

U

Measuring height in the touch probe axis

Q261

(absolute): coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.

U

U

U

U

Clearance height

Q260 (absolute): coordinate in the

touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.

U

U

U

U

Maximum dimension

Q288: maximum permissible

diameter of bolt hole circle.

U

U

U

U

Minimum dimension

Q289: minimum permissible

diameter of bolt hole circle.

U

U

U

U

Tolerance value for center 1st axis

Q279:

permissible position deviation in the reference axis of
the working plane.

U

U

U

U

Tolerance value for center 2nd axis

Q280:

permissible position deviation in the minor axis of the
working plane