60

3 Touch Probe Cycles for Automatic Workpiece Inspection

3.2 A

u

to

matic D

at

u

m Set

ting

DATUM IN TOUCH PROBE AXIS (touch probe
cycle 417, ISO: G417)

Touch probe cycle 417 measures any coordinate in the touch probe
axis and defines it as datum. If desired, the TNC can also enter the
measured coordinate into a datum table.

1

The TNC positions the touch probe to the starting points at rapid
traverse (value from MP6150 or MP6361) following the positioning
logic (see “Running touch probe cycles” on page 7) to the
programmed starting point

1

. The TNC offsets the touch probe by

the safety clearance in the positive direction of the touch probe
axis.

2

Then the touch probe moves in its own axis to the coordinate
entered as starting point

1

and measures the actual position with

a simple probing movement.

3

Finally the TNC returns the touch probe to the clearance height and
sets the datum in the touch probe axis, or enters its coordinates in
the active datum table.

U

U

U

U

First measuring point in the 1st axis

Q263

(absolute): coordinate of the first touch point in the
reference axis of the working plane.

U

U

U

U

First measuring point in the 2nd axis

Q264

(absolute): coordinate of the first touch point in the
minor axis of the working plane.

U

U

U

U

First measuring point in the 3rd axis

Q294

(absolute): coordinate of the first touch point in the
touch probe axis.

U

U

U

U

Setup clearance

Q320 (incremental): additional

distance between measuring point and ball tip. Q320
is added to MP6140.

U

U

U

U

Clearance height

Q260 (absolute): coordinate in the

touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.

U

U

U

U

Datum number in table

Q305: Enter the datum

number in the table in which the TNC is to save the
coordinate. If you enter Q305=0, the TNC
automatically sets the display so that the new datum
is on the probed surface.

U

U

U

U

New datum for touch probe axis

Q333 (absolute):

coordinate in the touch probe axis at which the TNC
should set the datum. Basic setting = 0

Example: NC blocks

5 TCH PROBE 417 DATUM IN TS AXIS

Q263=+25 ;1ST POINT 1ST AXIS

Q264=+25 ;1ST POINT 2ND AXIS

Q294=+25 ;1ST POINT 3RD AXIS

Q320=0 ;SET-UP CLEARANCE

Q260=+50 ;CLEARANCE HEIGHT

Q305=0 ;NO. IN TABLE

Q333=+0 ;DATUM

1

X

Z

Q260

Q294

MP6140

+

Q320

1

Before programming, note the following:

Before a cycle definition you must have programmed a
tool call to define the touch probe axis. The TNC then sets
the datum in this axis.