Enabling private line auto ring-down

The private line auto ring-down (PLAR) function enables a subscriber line to automatically call the
specified called number when the phone goes off-hook.
To configure the PLAR function:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter subscriber line view.

subscriber-line line-number N/A

3.

Configure PLAR.

private-line string

By default, PLAR is not configured.

Configuring a number match mode

Two number match modes are available: longest match and shortest match.
Suppose you have configured match-template 0106688 on a voice entity and match-template
01066880011 on another voice entity.
When a subscriber dials 01066880011:

If shortest match is used, the router matches and calls the number 0106688.

If longest match is used, the router matches and calls the number 01066880011.

When a subscriber dials 0106688:

If shortest match is used, the router immediately matches and calls the number 0106688.

If longest match is used, the router waits until the dial timer expires. Then the router matches the
received number against match templates. If a match is found, the router calls the matching number.

If no match is found, the router releases the call.

You can configure a terminator that identifies the end of a number. Suppose the terminator is the pound
sign #. When a subscriber dials 0106688#, the router immediately matches the number 0106688 with

match templates regardless of whether longest match is used. If a match is found, the router calls the

matching number.

Procedure

To configure a number match mode:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter voice view.

voice-setup

N/A

3.

Enter dial program view.

dial-program

N/A

4.

Configure a number match
mode.

number-match { longest |
shortest }

By default, shortest match is used.

5.

Configure a terminator.

terminator character

By default, no terminator is
configured.