H3C Technologies H3C MSR 5600 User Manual
Page 36
26
[RouterA-voice-dial] entity 1000 pots
[RouterA-voice-dial-entity1000] match-template 1000
[RouterA-voice-dial-entity1000] line 5/0
[RouterA-voice-dial-entity1000] return
# Enter the view of E&M interface 5/0.
[RouterA] subscriber-line 5/0
# Configure the immediate start mode (optional, because the default is the immediate start mode).
[RouterA-subscriber-line5/0] signal immediate
# Enable the PLAR function.
[RouterA-subscriber-line5/0] private-line 2000
# Enable the E&M non-signaling mode.
[RouterA-subscriber-line5/0] open-trunk caller
# Enable E&M analog control signals pass-through.
[RouterA-subscriber-line5/0] passthrough
# Disable the echo cancellation function.
[RouterA-subscriber-line5/0] undo echo-canceler enable
2.
Configure Router B:
# Configure the called number as 1000 for VoIP entity 1000, and configure the destination IP
address as 1.1.1.1.
[RouterB] voice-setup
[RouterB-voice] dial-program
[RouterB-voice-dial] entity 1000 voip
[RouterB-voice-dial-entity10] match-template 1000
[RouterB-voice-dial-entity10] address sip ip 1.1.1.1
[RouterB-voice-dial-entity10] quit
# Configure the local number as 2000 for POTS entity 2000, and bind E&M interface line 5/0 to
the POTS entity.
[RouterB-voice-dial] entity 2000 pots
[RouterB-voice-dial-entity2000] match-template 2000
[RouterB-voice-dial-entity2000] line 5/0
[RouterB-voice-dial-entity2000] return
# Enter the view of E&M interface 5/0.
[RouterB] subscriber-line 5/0
# Configure the immediate start mode (optional, because the default is the immediate start mode).
[RouterB-subscriber-line5/0] signal immediate
# Enable the E&M non-signaling mode.
[RouterB-subscriber-line5/0] open-trunk called
# Enable E&M control signals pass-through.
[RouterB-subscriber-line5/0] passthrough
# Disable the echo cancellation function.
[RouterB-subscriber-line5/0] undo echo-canceler enable