beautypg.com

Configuring an e&m interface, Configuring the cable type, Configuring the signal type – H3C Technologies H3C MSR 5600 User Manual

Page 22: Configuring a start mode for e&m signaling

background image

12

Step Command

Remarks

2.

Enter FXO interface view.

subscriber-line line-number

N/A

3.

Bind an FXS interface to the

FXO interface.

hookoff-mode delay bind
fxs_subscriber_line [ ring-immediately ]

By default, no FXS interface is
bound.

4.

Enable the PLAR function.

private-line string

By default, the PLAR function is
disabled.
For more information about this

command, see Voice Command
Reference
.

5.

Configure the interval

between on-hook and

off-hook.

timer hookoff-interval milliseconds

The default is 500 milliseconds.

Configuring an E&M interface

Configuring the cable type

You must configure the same cable type for the E&M interfaces on the originating and terminating

devices. Otherwise, only one-way voice communication can be implemented.
To configure the cable type for an E&M interface:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter E&M interface view.

subscriber-line line-number N/A

3.

Configure the cable type for
the E&M interface.

cable { 2-wire | 4-wire }

The default is 4-wire.

Configuring the signal type

You must configure the same signal type on the originating and terminating devices.
To configure the signal type for an E&M interface:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter E&M interface view.

subscriber-line line-number N/A

3.

Configure a signal type for the
E&M interface.

type { 1 | 2 | 3 | 5 }

The default is 5 (corresponding V
type signal).

Configuring a start mode for E&M signaling