21

Step Command

Remarks

2.

Enter voice view.

voice-setup

N/A

3.

Adjust echo cancellation
parameters.

echo-canceler { convergence-rate
value | max-amplitude value |
mix-proportion-ratio value |

talk-threshold value }

By default, the convergence rate of
comfort noise amplitude is 0, the
maximum amplitude of comfort

noise is 256, the comfort noise

mixture proportion control factor is
100, and the two-way judgment

threshold is 1.
The echo-canceler enable

command must be configured for

the configured parameters to take
effect.

Enabling the nonlinear function of echo cancellation

After echo cancellation is enabled, nonlinear parts in the line can cause residual echo. The nonlinear

function, also called residual echo suppression, can remove the residual echo.
To enable the nonlinear function of echo cancellation:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter voice interface view.

subscriber-line line-number

N/A

3.

Enable the nonlinear function

of echo cancellation.

nlp-on

By default, this function is enabled.
This command is available only

after you configure the
echo-canceler enable command.

Displaying and maintaining analog voice

interfaces

Execute display commands in any view.

Task Command

Display information about analog voice
interfaces.

display voice subscriber-line

Analog voice interface configuration examples

Two-dial configuration example for the FXO interface

As shown in

Figure 9

, Router A and Router B are connected through an IP network and can reach each

other. The PBX is configured with a trunk number 07552003.