beautypg.com

Configuration procedure, Setting the electrical impedance – H3C Technologies H3C MSR 5600 User Manual

Page 14

background image

4

To ensure correct call time, make sure the router system time transmitted in data-message format

stays synchronous with the local standard time.

For the CID function to operate correctly, keep the cid send command enabled.

Configuration procedure

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter FXS interface view.

subscriber-line line-number N/A

3.

(Optional.) Configure the
calling name for the FXS

interface.

calling-name text

By default, no calling name is configured.
The calling name can be sent only in the

multiple-data-message format.
Use this command on the originating
device.

4.

Enable the FXS interface

to send CID to the remote
end.

cid send

Optional.
By default, this function is enabled.
Use this command on the originating
device.

5.

Configure the standard

mode for sending CID.

cid standard-type { bellcore |
brazil }

By default, the bellcore mode is used.
This command is for use on the
terminating device, which encapsulates

the CID by using the configured standard

mode and sends it to the called

telephone.
The message format configured by using
the cid type command takes effect only

when the bellcore mode is used.

6.

Configure the data

message format.

cid type { complex | simple }

The default is complex.
Use this command on the terminating
device.
When the originating device supports

only one message format, you must use
that message format on the terminating

device.

7.

Enable CID on the FXS

interface.

cid display

By default, CID is enabled.
Use this command on the terminating
device.

Setting the electrical impedance

The electrical impedance setting must be subject to country specifications. Each country corresponds to

an impedance value. You specify an impedance value while specifying a country.
To set the electrical impedance:

Step Command

Remarks

1.

Enter system view.

system-view

N/A