Verifying the configuration, E1 dss1 signaling configuration example, Network requirements – H3C Technologies H3C MSR 5600 User Manual
Page 57
47
[RouterB-GigabitEthernet0/0] quit
# Create a timeslot set on interface E1 5/0.
[RouterB] controller e1 5/0
[RouterB-E1 5/0] timeslot-set 1 timeslot-list 1-31 signal r2
[RouterB-E1 5/0] quit
# Configure the local number 07552001 for POTS entity 2001, and bind the digital voice
interfaces line 5/0:1 to the POTS entity.
[RouterB] voice-setup
[RouterB-voice] dial-program
[RouterB-voice-dial] entity 2001 pots
[RouterB-voice-dial-entity2001] match-template 07552001
[RouterB-voice-dial-entity2001] line 5/0:1
[RouterB-voice-dial-entity2001] send-number all
[RouterB-voice-dial-entity2001] quit
# Configure the local number 07552002 for POTS entity 2002, and bind the digital voice
interfaces line 5/0:1 to the POTS entity.
[RouterB-voice-dial] entity 2002 pots
[RouterB-voice-dial-entity2002] match-template 07552002
[RouterB-voice-dial-entity2002] line 5/0:1
[RouterB-voice-dial-entity2002] send-number all
[RouterB-voice-dial-entity2002] quit
# Configure the called number template 010…. for VoIP entity 010, and configure the destination
IP address as 1.1.1.1.
[RouterB-voice-dial] entity 010 voip
[RouterB-voice-dial-entity10] match-template 010....
[RouterB-voice-dial-entity10] address ip 1.1.1.1
Verifying the configuration
The telephones can call each other through R2 signaling. You can use the display voice subscriber-line
command to view information about digital voice interfaces.
E1 DSS1 signaling configuration example
Network requirements
As shown in
, the routers connect to the PBXs through E1 interfaces.
Configure DSS1 signaling on the routers so the telephones can call each other.