Reference lines distance offset, Advanced settings "implement – ARAG Bravo 400S Seletron User Manual
Page 41
![background image](https://www.manualsdir.com/files/811971/content/doc041.png)
41
END 10.1.12 Working parameters
ADVANCED SETTINGS
"IMPLEMENT"
• Reference lines distance offset
This value allows changing the distance between the reference tracks.
Fig. 133
+0.5 m
+0.5 m
Fig. 134
When the value is positive, the distance between the
reference tracks (black lines) decreases.
The spray lateral sides overlap.
Fig. 135
-0.5 m
-0.5 m
Fig. 136
When the value is negative, the
distance between the reference tracks
(black lines) increases.
Unsprayed spaces are left between
one spray and the other.
Par.
Exit the function or
data change
Confirm access
or data change
Scroll
(LEFT / RIGHT)
Delete
selected
character
Increase /
decrease
value
Scroll
(UP / DOWN)
Enter
selected
character