beautypg.com

18 technical data, 1 data and units of measurement shown, Technical data – ARAG Bravo 400S Seletron User Manual

Page 113

background image

113

18

TECHNICAL DATA

DESCRIPTION

Bravo 400S

Display

LCD 5,7", 65000 colors, 500 cd/m

2

Rated supply voltage

12 Vdc (9 ÷ 15 Vdc)

Consumption (valves excluded)

monitor: 0.4 A / Seletron RCU: 0.6 A / hydraulic RCU: 1.5 A

Operating temperature

0 °C ÷ 45 °C

+32 °F ÷ +113 °F

Storage temperature

-20 °C ÷ 45 °C

-4 °F ÷ +113 °F

Digital inputs

for open collector sensors: max 2000 imp*/s

Analog input

4 ÷ 20 mA

Weight (without cables)

monitor: 1567 g (Bravo code 4674A9D20.950)

RCU: 1143 g

SD card reader

2 USB 2.0 ports

HOST

Protection against polarity inversion

Protection against short-circuit

18.1

Data and units of measurement shown

Implement

Menu

Data

Min. Max.

UoM

DEFAULT

Other values that can be set / Notes

Spray spots
configuration

Number of nozzles for each spraying point

--

--

1

2, 4

Selection during guided setup

Spraying point 1

Nozzle A

--

--

--

Nozzle:

,

,

,

,

,

,

,

,

,

,

,

,

,

,

,

,

,

Nozzle B

--

--

--

Disabled

Nozzle C

--

--

--

Disabled

Nozzle D

--

--

--

Disabled

Spraying point 2

Nozzle A

--

--

--

Nozzle B

--

--

--

Disabled

Nozzle C

--

--

--

Disabled

Nozzle D

--

--

--

Disabled

Spraying point 3

Nozzle A

--

--

--

Nozzle B

--

--

--

Disabled

Nozzle C

--

--

--

Disabled

Nozzle D

--

--

--

Disabled

Spraying point 4 ÷ 20

--

--

--

Disabled

Boom settings

Spray spots spacing

1

1000

cm

50 cm

0.39 393.70 inches

19.68 inches

Number of sections

1

13

9

Section 1 ÷ 13

1

50

4

Number of spraying points for each section

Activation status of the
sections

Section 1 ÷ 13

--

--

--

Enabled

Disabled

Flowmeter

Type

--

--

--

Orion

462xxA4xxxx

Orion 4621xA0xxxx, Orion 4621xA1xxxx, Orion 4621xA2xxxx,
Orion 4621xA3xxxx, Orion 4622xA5xxxx, Orion 4622xA6xxxx,
Wolf 462x2xxx, Wolf 462x3xxx, Wolf 462x4xxx, Wolf 462x5xxx,
Wolf 462x7xxx,

Other

Constant

1

32000

pls*/l

--

Fixed settings for each flowmeter except

Other

4

32000 pls*/gal

--

Minimum flowrate

0.1

999.9

l/min

--

0.1

264.1

GPM

--

Maximum flowrate

0.1

999.9

l/min

--

0.1

264.1

GPM

--

Filling flowmeter

Type

--

--

--

Orion

462xxA4xxxx

Orion 4622xA5xxxx, Orion 4622xA6xxxx,
Wolf 462x4xxx, Wolf 462x5xxx, Wolf 462x7xxx,

Other

Constant

1

32000

pls*/l

--

Fixed settings for each flowmeter except

Other

4

32000 pls*/gal

--

Minimum flowrate

0.1

999.9

l/min

--

0.1

264.1

GPM

--

Maximum flowrate

0.1

999.9

l/min

--

0.1

264.1

GPM

--

Pressure sensor

Activation status

--

--

--

Disabled

Enabled

Type

--

--

--

466113.200

466113.500,

Other

Maximum pressure

0.1

150.0

bar

--

Fixed settings for each sensor except

Other

1

2175

PSI

--

Valves

Main valve

Type

--

--

--

3 ways

2 ways,
None

Selection during guided setup

Automatic closing of
sections valves

--

--

--

Enabled

Disabled

Selection during guided setup

Automatic closing
of main valve

--

--

--

Disabled

Enabled

Switching time

0.1

1.0

s

1.0 s

Pressure regulating
valve

Regulation direction

--

--

--

Standard

Reverse

Section valves

Type

--

--

--

2 ways

Automatic selection during guided setup

Shut-off time

0.1

1.0

s

0.3 s

Switch-on time

0.1

1.0

s

0.3 s

TECHNICAL DATA

* pls = pulse

CONTINUES > > >