beautypg.com

Technical data – ARAG Bravo 400S Seletron User Manual

Page 114

background image

114

Menu

Data

Min. Max.

UoM

DEFAULT

Other values that can be set / Notes

Nozzles data

Flowrate

--

--

l/min

0.40 l/min

ISO nozzles - cannot be modified

--

--

GPM

0.10 GPM

Flowrate

--

--

l/min

0.60 l/min

--

--

GPM

0.15 GPM

Flowrate

--

--

l/min

0.80 l/min

--

--

GPM

0.20 GPM

Flowrate

--

--

l/min

1.00 l/min

--

--

GPM

0.25 GPM

Flowrate

--

--

l/min

1.20 l/min

--

--

GPM

0.30 GPM

Flowrate

--

--

l/min

1.60 l/min

--

--

GPM

0.40 GPM

Flowrate

--

--

l/min

2.00 l/min

--

--

GPM

0.50 GPM

Flowrate

--

--

l/min

2.40 l/min

--

--

GPM

0.60 GPM

Flowrate

--

--

l/min

3.20 l/min

--

--

GPM

0.80 GPM

Flowrate

--

--

l/min

4.00 l/min

--

--

GPM

1.00 GPM

Flowrate

--

--

l/min

6.00 l/min

--

--

GPM

1.50 GPM

Flowrate

--

--

l/min

8.00 l/min

--

--

GPM

2.00 GPM

Pressure

--

--

bar

3.0 bar

--

--

PSI

40 PSI

Flowrate

0.10

10.00

l/min

1.00 l/min

User nozzles - customizable

0.03

2.6

GPM

0.26 GPM

Flowrate

0.10

10.00

l/min

2.00 l/min

0.03

2.6

GPM

0.53 GPM

Flowrate

0.10

10.00

l/min

3.00 l/min

0.03

2.6

GPM

0.79 GPM

Flowrate

0.10

10.00

l/min

4.00 l/min

0.03

2.6

GPM

1.06 GPM

Flowrate

0.10

10.00

l/min

5.00 l/min

0.03

2.6

GPM

1.32 GPM

Flowrate

0.10

10.00

l/min

6.00 l/min

0.03

2.6

GPM

1.59 GPM

Pressure

0.1

50.0

bar

5.0 bar

1.45

725

PSI

70 PSI

Minimum pressure

0.1

50.0

bar

Default ISO nozzles:
1.0 ÷ 5.0 bar
15 ÷ 70 PSI
Default user nozzles:
2.0 ÷ 10.0 bar
30 ÷ 145 PSI

1.45

725

PSI

Maximum pressure

0.1

50.0

bar

1.45

725

PSI

Wheel sensor

Constant

0.01 2000.00 cm/pls*

38.33 cm/pls*

0.01

780.00 inch/pls* 15.09 inch/pls*

Rev counter

Activation status

--

--

--

Disabled

Enabled

Constant

1

999

pls*/rev** 100 pls*/rev**

Minimum rotation speed

1

10000

rpm

100 rpm

Maximum rotation speed

1

10000

rpm

500 rpm

Tank

Reserve level

1

2000

l

150 l

1

500

gal

40 gal

Capacity

1

99999

l

2000 l

Can be viewed only with

Filling flowmeter enabled

or

manual tank level source

(selection during guided setup)

1

25000

gal

528 gal

Tank profile

--

--

--

--

Visible only with

Level sensor enabled

(selection during guided setup)

Alarms

Nozzles alarms

Nozzle wear check

--

--

--

Disabled

Enabled
Visible ONLY with

Pressure sensor enabled

Nozzle wear limit percentage

1

50

%

10 %

Visible ONLY with

Pressure sensor enabled

Minimum pressure alarm

--

--

--

Disabled

Enabled

Maximum pressure alarm

--

--

--

Disabled

Enabled

Flowmeter alarms

Minimum flowrate alarm

--

--

--

Disabled

Enabled

Maximum flowrate alarm

--

--

--

Disabled

Enabled

Rev counter alarms

Minimum speed alarm

--

--

--

Disabled

Enabled

Maximum speed alarm

--

--

--

Disabled

Enabled

TECHNICAL DATA

* pls = pulse

** rev = revolution

CONTINUES > > >

> > > 18.1 Data and units of measurement shown

Implement