2 troubleshooting, 3 cleaning rules, 2 troubleshooting 17.3 cleaning rules – ARAG Bravo 400S Seletron User Manual
Page 112: Maintenance / diagnostics / repairs
112
17.2
Troubleshooting
FAULT
CAUSE
REMEDY
The display does not switch on
No power supply
• Check power supply connection
Computer is OFF
• Press the ON key
Valve controls take no effect
Valves not connected
• Connect the connectors
One valve does not open
No power supply to valve
• Check valve electric connection and operation
Speed reading is unstable
Job start procedure was launched at a point too far from
the field to be sprayed
• Start a new job
(par. 12.5) close to the field.
Output volume readout inaccurate
Wrong setup
• Check boom setup
(par. 10.1.2)
• Check the setup of the flowmeter constant
(par. 10.1.3)
• Check pressure sensor full scale setting
(par. 10.1.5)
Distance traveled count displayed does not
match actual distance covered
Wrong setup
• Check the boom setup (par. 10.1.2)
• Check implement geometry (par. 10.1.14 - 10.1.15)
• Check tractor geometry (par. 10.2.9)
Sprayed fluid count displayed does not match
liters/gal actually sprayed
Wrong setup
• Check the setup of the flowmeter constant
(par. 10.1.3)
• Check selected nozzle configuration
(par. 10.1.1 - par.
Unable to reach output volume value set for the
automatic operation
Wrong setup
• Check spray rate setup (par. 12.5 - 16.1)
• Check setup of boom width (par. 10.1.2)
System not adequately sized to provide required rate
• Check maximum pressure valve adjustment
• Make sure control valve is adequate for specific system
Control valve malfunction
• Check valve operation
Instantaneous pressure readout inaccurate
Wrong setup
• Check full scale setup for pressure sensor
(par. 10.1.5)
Pressure sensor not calibrated
• Perform the calibration
(par. 10.1.13)
Pressure sensor wrong installation
• Check connections to pressure sensor
Instantaneous pressure is not displayed
Wrong setup
• Check pressure sensor setting
(par. 10.1.5)
Computer does not receive signals from pressure sensor • Check connections to pressure sensor
Pressure sensor wrong installation
• Check connections to pressure sensor
Rpm readout inaccurate
Wrong setup
• Check rpm sensor constant setting
(par. 10.1.9)
Rpm value not displayed
Monitor does not receive signals from RPM sensor
• Check connections to RPM sensor
Rpm sensor wrong installation
• Check connections to RPM sensor
17.3
Cleaning rules
- Clean only with a soft wet cloth.
- DO NOT use aggressive detergents or products.
- DO NOT aim water jets directly at monitor and control unit.
Fig. 386
MAINTENANCE / DIAGNOSTICS / REPAIRS