Troubleshooting

FAULT

CAUSE

REMEDY

The display does not switch on

No power supply

• Check power supply connection

Computer is OFF

• Press the ON key

Valve controls take no effect

Valves not connected

• Connect the connectors

One valve does not open

No power supply to valve

• Check valve electric connection and operation

Speed reading is unstable

Job start procedure was launched at a point too far from
the field to be sprayed

• Start a new job

(par. 12.5) close to the field.

Output volume readout inaccurate

Wrong setup

• Check boom setup

(par. 10.1.2)

• Check the setup of the flowmeter constant

(par. 10.1.3)

• Check pressure sensor full scale setting

(par. 10.1.5)

Distance traveled count displayed does not
match actual distance covered

Wrong setup

• Check the boom setup (par. 10.1.2)

• Check implement geometry (par. 10.1.14 - 10.1.15)

• Check tractor geometry (par. 10.2.9)

Sprayed fluid count displayed does not match
liters/gal actually sprayed

Wrong setup

• Check the setup of the flowmeter constant

(par. 10.1.3)

• Check selected nozzle configuration

(par. 10.1.1 - par.

12.5)

Unable to reach output volume value set for the
automatic operation

Wrong setup

• Check spray rate setup (par. 12.5 - 16.1)

• Check setup of boom width (par. 10.1.2)

System not adequately sized to provide required rate

• Check maximum pressure valve adjustment
• Make sure control valve is adequate for specific system

Control valve malfunction

• Check valve operation

Instantaneous pressure readout inaccurate

Wrong setup

• Check full scale setup for pressure sensor

(par. 10.1.5)

Pressure sensor not calibrated

• Perform the calibration

(par. 10.1.13)

Pressure sensor wrong installation

• Check connections to pressure sensor

Instantaneous pressure is not displayed

Wrong setup

• Check pressure sensor setting

(par. 10.1.5)

Computer does not receive signals from pressure sensor • Check connections to pressure sensor
Pressure sensor wrong installation

• Check connections to pressure sensor

Rpm readout inaccurate

Wrong setup

• Check rpm sensor constant setting

(par. 10.1.9)

Rpm value not displayed

Monitor does not receive signals from RPM sensor

• Check connections to RPM sensor

Rpm sensor wrong installation

• Check connections to RPM sensor

17.3

Cleaning rules

- Clean only with a soft wet cloth.
- DO NOT use aggressive detergents or products.
- DO NOT aim water jets directly at monitor and control unit.

Fig. 386

MAINTENANCE / DIAGNOSTICS / REPAIRS