WIRING CONNECTIONS
• Use only the cables provided with the ARAG computers.
• Take care not to break, pull, tear or cut the cables.
• Use of unsuitable cables not provided by ARAG automatically voids the warranty.
• ARAG is not liable for damages to the equipment, persons or animals caused by failure to observe the above instructions.
6.1
General precautions for a correct harness position
• Securing the cables:
- Secure the harness so that it does not interfere with moving parts.
- Route the harnesses so that they cannot be damaged or broken by machine movements or twisting.
• Routing the cables to protect against water infiltrations:
- The cable branches must ALWAYS be facing downwards (Fig. 10).
Fig. 10
Fig. 11
• Fitting the cables to the connection points:
- Do not force the connectors by pushing too hard or bending them: the contacts may be damaged and computer operation may be compromized.
Use ONLY the cables and accessories indicated in the catalog, having technical features suitable for the use to be made of them.
6.2
Switch panel connection
The package includes the cable to connect switch panel and monitor (components 3, Fig. 1 and Fig. 2).
Fix the connectors (see connection points at par. 5.2) and, after ensuring it is correctly in place, turn the ring nut clockwise until blocking it.
6.3
Connecting the Remote Control Units (RCU) (Seletron RCU and hydraulic RCU)
Connect harnesses as specified in par. 5.2; each one of them shall be connected to the corresponding socket on the remote control unit.
If they prove hard to insert, do not force them, but check the shown position.
Fig. 12
• Open connector slide (
1
• Position connector (
2
) and insert it inside socket (
3
), then press:
during this operation, take special care not to bend electric contacts.
• Close slide (
4
) until it locks in place.