Spray closing delay, Spray opening advance, Guidance – ARAG Bravo 400S Seletron User Manual
Page 40: Steering radius, Advanced settings "implement

40
> > > 10.1.12 Working parameters
• Spray closing delay
Indicate the distance corresponding to the delayed closing of sections during spraying, to ensure correct spraying range.
NOTE: Negative values indicate that sections are closed in advance with respect to the calculated point.
Fig. 127
Closing delay: 0.3 m
Fig. 128
• Spray opening advance
Indicate the distance corresponding to the advanced opening of sections during spraying, to ensure correct spraying range.
NOTE: Negative values indicate that section opening is delayed with respect to the calculated point.
Fig. 129
Opening advance: 0.3 m
Fig. 130
GUIDANCE
• Steering radius
By setting this value, an acoustic alarm will indicate the exact moment when the operator must steer in order to align the machine with the following track, avoiding
unsprayed or overlapping areas between the two sprays.
The acoustic alarm may be enabled or disabled from the
User > Steering warning
menu
(par. 10.3.4).
This distance should correspond to the implement steering radius (
A
in Fig. 132), used at the end of the field to change driving direction and resume spraying on the
next track, but it will have to be adjusted according to the characteristics of the operator and the speed of the machine.
The alarm is triggered ONLY if the direction of the machine is at an angle of more than 85° with respect to the next track.
Fig. 131
A
Fig. 132
ADVANCED SETTINGS
"IMPLEMENT"
CONTINUES > > >
Par.
Exit the function or
data change
Confirm access
or data change
Scroll
(LEFT / RIGHT)
Delete
selected
character
Increase /
decrease
value
Scroll
(UP / DOWN)
Enter
selected
character