Westermo ID-90 User Manual
Page 88
88
6607-2204
To use Alarm inputs for SMS Call and MINICALL paging.
To set the alarm input 1 to be triggered on a contact breaking condition and transfer
a SMS or MINICALL text message to a receiver GSM telephone or a MINICALL.
For example a house supervision alarm system.
1
2
3
4
5
6
7
8
9
▼▼
▼▼
ATCONF
Set ID-90 in configuration mode
OK
#
Configurator prompt
OPNUMBER1 00491722278000
Number to SMS/MINICALL service provider
#
MESSAGE1 Main Door Opened
Text message to sent
#
MTYPE1 0
0 = SMS/MINICALL (default), 1 = Hotline text
#
RECNO1 0172555555
GSM number that will receive the text message
#
TRANSNO 01721234567
Calling party number
#
MAXRETRIES 4
Number of times ID-90 will retry to send after
#
failed transmission
TRIGCND1 1
0 = No cond.(default) 1 = Break cond. 2 = Make
#
cond.
SAVE
Save above parameters in EEPROM
#
EXIT
Exit from configurator and enter AT-command
mode
Note: It is of importance that you check the physical connection to the alarm inputs
before setting parameter trigcnd to avoid unintentional transmission of alarm
messages.