Message – text message setting, Msn – multiple subscriber number, Mtype – transfer method for alarm message – Westermo ID-90 User Manual
Page 77
77
6607-2204
maxretries – Max number of retries on sending
alarm messages
With this command you can set the maximum allowed retries on sending an alarm mes-
sage. The highest allowed value for maxretries = 9 (default = 0).
message – Text message setting
With this command you can set the message text that will be sent at an alarm trig.
There is one entry for each alarm input.
messagex
mm
Set entry number x to message text mm.
messagex
-
Clear entry number x.
messagex
Show entry number x.
message
Show all entries.
Maximum number of entries = 4.
Maximum length of message text = 20.
Example: message command (show all entries)
message1:
Alarm on input 1
message2:
Motor 4 over temp
message3:
message4:
msn – Multiple Subscriber Number
Own MSN (Multiple Subscriber Number)
*: no specific MSN, all incoming calls accepted
The msn is automatically stored to non volatile ram.
mtype – Transfer method for alarm message
With this command you can set up the transfer method for an alarm message.
Selectable transfer methods are SMS, and Hotline text
There is one mtype entry for each alarm input.
mtypex
n
Set entry number x to method number n.
mtypex
-
Clear entry number x
mtypex
?
Show all selectable transfer methods
mtypex
Show entry number x
mtype
Show all entries
Maximum number of entries = 4.
0:
SMS text (UCP) according to UCP- (Universal Computer Protocol)
(default)
1:
Hotline text (expects a
avoid retries)
2:
SMS text (TAP) (Telocator Alpanumeric Protocol)