Recno – alarm message receiver number, Reset – reset id-90, Ringtimer – delay of ring messages – Westermo ID-90 User Manual
Page 80: Rmmsg – message for remote access, Rmsn – multiple subscriber number for remote, Rpwd – password
recno – Alarm message receiver number
With this command you can set up the receivers number of a alarm message.
There is one entry for each alarm input.
recnox
nn
set entry number x to receiver number nn.
recnox
-
clear entry number x
recnox
show entry number x
recno
show all entries
Maximum number of entries = 4.
Maximum length of receiver number = 20 digits.
Example: recno command (show all entries)
recno1:
01661200
recno2:
049701098505
recno3:
046609734
recno4:
reset – Reset ID-90
Resets the whole functionality of the ID-90 by a forced hardware reset.
ringtimer – Delay of RING messages
Delaytime between two RING messages, if S0 register is set not equal to 1,
value in 100 ms.
Default: ringtimer = 50 (5 sec).
rmmsg – Message for remote access
Display message on the local port, “rmon” for established “rmoff” for disconneced
remote configuration access. If an PAD connection is established the message will be
discarded.
0: display no messages (default)
1: display messages
rmsn – Multiple Subscriber Number for remote
MSN (Multiple Subscriber Number) for remote configuration
*: no specific MSN, all incoming calls accepted
rpwd – Password
Password for remote configuration (character input)
To disable password please enter: rpwd –