Westermo ID-90 User Manual
Page 50

50
6607-2204
Parameter of the integrated PAD
Using the PAD command “set x:n” you can change the parameter according to ITU
specification X.3.
After changing one or more X.3 parameter you can store the change non volatile by issu-
ing “exec save”. The stored parameter can be reloaded with the command “exec load”.
After an X.25 connection is cleared the PAD parameter will be reset to the last active pro-
file (rsp. default).
International Parameters 1 through 12
1
Enable (disable) switch to command mode
Defines whether the terminal user may switch from data to command
mode (e.g. to change a X.3 parameter), and – if he may – which key(s)
must be pressed to make the switch.
Valid Parameter Values:
0
Switch to command mode disabled.
1
Switch to command mode enabled
switch by pressing the key combination
n
Switch to command mode enabled
switch by entering the ASCII character, that corresponds to the parameter
value n (decimal integer value in the range between 32 and 126).
2
Echo
Determines whether a character will be echoed to the terminal data
transfer mode.
Valid Parameter Values:
0
No echo
1
Echo