atsx, atopt, atrej – AT command parameter set

AT command set only:

Handle AT specific settings.
Show and change AT S registers by entering the new value.
ats0

show setting of S0-Register

ats0=1

set Register S0 to 1

atopt

show option register (bit-values):

bit 0: 0

1 => ATV1

bit 1

: 02 => ATW1

bit 2

: 04 => ATQ1

bit 3

: 08 => ATE1

bit 4

: 10 => ATS9=0

atrej

show reject register => setting of AT#R (0,1)

autoreset – TA reset option

The autoreset command is default 0 but if value is 1 then the unit make a reset every time
a disconnect occurs.
If the value is more that 1 and less that 255 the unit resets periodically every minute spec-
ified by this command.

Example: autoreset=0 (default)

autoreset=1
autoreset=20

bc – Bearer capability

Bearer capability for outgoing data calls. (default: 00 00; hex bytes) (see note 2, page 84)

bod – Bandwidth On Demand enable

0 disable BOD (default)
1 enable BOD

bodiv – BOD increase value

bodiv= Set the bit-rate in kbit/s at which a second B channel is

connection (default=40).

bodit – BOD increase timer

bodit=

Sets the time in seconds the bit-rate has to be over the
increase value before the second B-channel is connected
(default=30)