Catab – hot line table, Cato – call timeout to abort, Capa – call pause – Westermo ID-90 User Manual
Page 71: Catry – calls retry
71
6607-2204
catab – Hot line table
With this command the priority table of hot line DTR and TxD calling number is set-up
The ID-90 will call the numbers defined in order from catab1 to catab3 until a connection
is established. The character # is used as prefix to signal that the call shall use an ana-
logue connection
catabx
nn
set entry number x to receiver number nn.
catabx
-
clear entry number x
catabx
show entry number x
catab
show all entries
Maximum number of entries = 3
Maximum length of number = 20 digits.
In below example entry 1 tells ID-90 to make a call using the analogue modem, while
entry 2 and 3 making ISDN –ISDN connections.
Example:
catab1 #00461661200
catab2 004616480130
catab3 0123987652
cato – Call timeout to abort
Time to abort a call if not successfully connected after n seconds.
n = 3..255, (default 15 s).
capa – Call pause
Automatic call: set a call pause for n seconds before next call attempt.
n = 0 .. 255: n=0 no call retry, (default 3s).
catry – Calls retry
Automatic call: max. no of tries of every number entry in catab.
n = 1 .. 255 (default 1)