Flow control, Software update, Selection of analogue coding v-90 – Westermo ID-90 User Manual
Page 17

17
6607-2204
Flow control
Selects the flow control behaviour of the ID-90 while in data communication phase.
Stored setting from ID-90 database is used
S4
–
Related
AT-command
ON
1 2 3 4 5 6 7 8
No local flow control between the DTE and ID-90 is used CTS
is always ON, RTS ignored
S4
AT&K
AT&R1
ON
1 2 3 4 5 6 7 8
No local flow control between the DTE and ID-90 is used CTS
follows DTR, RTS ignored
S4
AT&K
AT&R2
ON
1 2 3 4 5 6 7 8
No local flow control between the DTE and ID-90 is used CTS
follows changes on RTS
S4
AT&K
AT&R
ON
1 2 3 4 5 6 7 8
Local flow control is set to hardware handshake RTS/CTS
S4
AT&K3
ON
1 2 3 4 5 6 7 8
Local flow control is set to software handshake XON/XOFF
CTS is always ON, RTS ignored
S4
AT&K4
AT&R1
ON
1 2 3 4 5 6 7 8
Local flow control is set to software handshake XON/XOFF
CTS follows DTR, RTS ignored
S4
AT&K4
AT&R2
ON
1 2 3 4 5 6 7 8
Local flow control is set to software handshake XON/XOFF
CTS follows changes on RTS
S4
AT&K4
AT&R
ON
1 2 3 4 5 6 7 8
Software update
Enable Flash programming, should always be in OFF position
for normal operation, ref. software update
S4
ON
1 2 3 4 5 6 7 8
Selection of analogue coding V-90
A-Law, European analogue data coding standard
S4
ON
1 2 3 4 5 6 7 8
µ-Law, US analogue data coding standard
S4
ON
1 2 3 4 5 6 7 8