Westermo ID-90 User Manual
Page 53

53
6607-2204
10
Screen Line Width
not suppported
11
Local baudrate (Read only)
Displays actual used baudrate on asynchronous line.
1: 1 200 bit/s
2: 2 400 bit/s
3: 4 800 bit/s
4: 9 600 bit/s
5: 19 200 bit/s
6: 38 400 bit/s
7: 57 600 bit/s
8: 115 200 bit/s
12
Local flow control (Read only)
Handles and displays used flow control on asynchronous line.
0: no flow control
3: flow control RTS / CTS
4: flow control XON / XOFF
Extended Parameters 13 through 24
13
Automatic Line Feed
Defines, whether the PAD should automatically append a line feed follow-
ing a carriage return
also.
Valid Parameter Values:
0
No
1
When receiving data from the remote party add a
after each
2
Add a
board.
4
By each echo of a
Note: This parameter is interpreted bit-wise, thus any combination of the above
listed values can be combined to form a sum of the desired values
14
Line Feed Fill Characters
Defines, whether fill characters
feed
Valid Parameter Values:
0
No fill characters
n
Following a
an integer in the range from 1 to 255.