S90 – Last incoming ISDN calling number (CLIP)
S90 displays the ISDN line identification of the last incoming call.
S91 – PSTN Transmit Attenuation Level
Only valid with analogue modem option
In non-PCM modes (V.90 or K56flex are PCM modes), S91 sets the transmit attenuation
level from 0 to 15 dBm for the PSTN mode, resulting in a transmit level from 0 to –15 dBm.
In some countries, the transmit level may not be changed. Default: 13.
S92 – Fax Transmit Attenuation Level
Only valid with analogue modem option
S92 sets the transmit attenuation level from 0 to 15 dBm for the fax mode, resulting in a
transmit level from 0 to –15 dBm. The fax mode is used when alarm message type (mtype)
is set to Fax. In some countries, the transmit level may not be changed. Default: 13.
S93 – Unknown AT command handling
Controls the response to unknown AT-commands
0
Undefined AT commands will be responded with ERROR (default)
1
Undefined AT commands will be responded with OK
S210 – V.34 Symbol Rates
The bits in this parameter control V.34 symbols rates and enables/disables V.34 asymmet-
ric rates. This parameter is used for diagnostic purpose only.
Bits 0–2
Selects the range of allowed V.34 symbol rates.
Bit
Symbol Rates (baud)
2
1
0
0
0
0
2 400 only
0
0
1
2 400 only (no 2 734)
0
1
0
2 400, 2 800
0
1
1
2 400, 2 800, 3 000
1
0
0
2 400, 2 800, 3 000, 3 200
1
0
1
2 400, 2 800, 3 000, 3 200, 3 429 (default)
Bit 3
Enable/disable V.34 asymmetric rates.
0 = Disable asymmetric rates
1 = Enable asymmetric rates (default)
Bits 4–7 Reserved.
Default: 13.