Westermo ID-90 User Manual
Page 55
55
6607-2204
19
Handling Delete Characters
Defines, what should be sent to the screen when a Character-Delete or
a Line-Delete character is received.
Valid Parameter Values:
0
Nothing
2
Send a
deleted.
20
Echo Filter
If parameter 2 is set to 1 (= character echo during data transfer), this
parameter can be used to determine which characters, entered from the
keyboard, will not be echoed to the screen.
Valid Parameter Values:
0
No echo filter, thus echo all characters
1
No echo for
2
No echo for
4
No echo for
8
No echo for
16
No echo for
32
No echo for
64
No echo for editing characters, those set with the parameters 118, 119,
and 120
128
No echo for or any other ASCII control character not listed
above
Note: This parameter is interpreted bitwise, thus any combination of the above
listed values can be combined to form a sum of the desired values
21
Parity handling (Read only)
Handles and displays used parity on asynchronous line.
0: no parity
1: even parity
2: odd parity
3: no parity