Boddv – bod decrease value, Boddt – bod decrease timer, Br – baudrate asynchronous – Westermo ID-90 User Manual
Page 70: Brn – line baudrate asynchronous v.110, Bsize – frame length
70
6607-2204
boddv – BOD decrease value
boddv=
disconnected (default=40).
boddt – BOD decrease timer
boddt=
Sets the time in seconds the bit-rate has to be under the
increase value before the second B-channel is disconnected
(default=30)
br – Baudrate asynchronous
Selection of the asynchronous baudrate for the DTE interface
0: Autobauding, (automatic local bit rate adaption) (default)
1: 1 200 bit/s
2: 2 400 bit/s
3: 4 800 bit/s
4: 9 600 bit/s
5: 19 200 bit/s
6: 38 400 bit/s
7: 57 600 bit/s
8: 115 200 bit/s
Note: Autobauding (br = 0) is available for AT command set only. If autobauding is
set and cmds is changed to PAD, br will be set to 4 (9 600 bit/s).
brn – Line baudrate asynchronous V.110
Selection of the asynchronous baudrate for V.110 line (B channel)
0: Line baudrate equals local baudrate
1: 1 200 bit/s
2: 2 400 bit/s
3: 4 800 bit/s
4: 9 600 bit/s
5: 19 200 bit/s
bsize – Frame length
Maximum length of a data frame (default 2048) Note changing the B-channel protocol
will affect the bsize parameter.
Values: 32 .. 2048