beautypg.com

Line baudrate at v.110, Factory settings – Westermo ID-90 User Manual

Page 18

background image

18

6607-2204

Default setting from ID-90 database is used

S4

Related

AT-command

ON

1 2 3 4 5 6 7 8

1200 bit/s

S4

ATN1

ON

1 2 3 4 5 6 7 8

2 400 bit/s

S4

ATN2

ON

1 2 3 4 5 6 7 8

4 800 bit/s

S4

ATN3

ON

1 2 3 4 5 6 7 8

9 600 bit/s

S4

ATN4

ON

1 2 3 4 5 6 7 8

19 200 bit/s

S4

ATN5

ON

1 2 3 4 5 6 7 8

Line baudrate at V.110

The ID-90 DIP-switches will be read at Power on and override the current database set-
ting. If an AT-command or Configurator command given after Power on addressing the
same parameter as a DIP-switch setting the command will in turn override the DIP-switch
setting.
A Save command AT&W will store the current configuration set by DIP-switches or
configuration commands.

Factory settings

S1

ON

1 2 3 4 5 6 7 8

S2

ON

1 2 3 4 5 6 7 8

S3

ON

1 2 3 4 5 6 7 8

ID-90 V.90

S4

ON

1 2 3 4 5 6 7 8

S1

ON

1 2 3 4 5 6 7 8

S2

ON

1 2 3 4 5 6 7 8

S3

ON

1 2 3 4 5 6 7 8

ID-90

S4

ON

1 2 3 4 5 6 7 8