6607-2204
Displays the allowed values for one selected command
acctab – isdn access control
This command enables the user to setup a table, to allow only dedicated users to make a
connection to the adapter.
Please also refer to the section ”ISDN access control”
alarm – Show alarm parameters
Lists the current setting of alarm parameters
alarm
OpNumber1: 00491722278000 OpNumber2: 00491712521002
OpNumber3: 02403745101041 OpNumber4:
message1: SMS via D2 Germany message2: SMS via D1 Germany
message3: Telia X31/X25 SMS message4: Plain test msg.
recno1: 01725555555 recno2: 01711234567 recno3: 0046123456789
recno4: 004616987654321 mtype1: 0-SMS (UCP) mtype2: 2-SMS (TAP)
mtype3: 0-SMS (UCP) mtype4: 1-Text TransNo: 00461661200
trigcnd1: 1-Break Cond. trigcnd2: 2-Make Cond.
trigcnd3: 1-Break Cond.
trigcnd4: 1-Break Cond. maxretries: 0 opwd1:
opwd2: PG1 opwd3:
opwd4:
alprot1: 0-X.75
alprot2: 0-X.75 alprot3: 1-X.31D
alprot4: 0-X.75
alprot – SMS message protocol
Defines the protocol used to communicate with the SMS operator. Protocol has to be
defined for each alarm message.
alprotx=0
Selects protocol to be X.75, normally used by operators on circuit
switched network. Also used for Hotline alarm text messages. (default)
alprotx=1
Selects protocol to be X.31 over D-channel, used when the SMS serv-
ice is accessed through a X.25 network.
alprotx=2
selects analogue protocol (only in ID-90 V90). Used when the SMS
service center has an analogue modem as connection point.
astatus – Show status of alarm inputs
This comand displays the status of the four alarm inputs.
Example:
A1: 0Contact open
A2: 1
Contact closed
A3: 0Contact open
A4: 0Contact open