Westermo GD-01 User Manual
Page 28
28
6196-2220
Command example
Possible responses
Note
AT+COPS?
+COPS: 0,2,20801
Ask for current PLMN,
OK
reported PLMN is
France Telecom Orange
AT+COPS=?
+COPS:
Ask for PLMN list, home
(2,”F Itinéris”,”Itline”,”20801”),
PLMN is France
OK
(3,”FSFR”,”SFR”,”20810”)
Telecom, SFR network
has been detected
AT+COPS=1,2,20810
+CME ERROR: 32
Ask for registration on
SFR network, network
not allowed – emergency
calls only
AT+COPS=1,1,23433
+CME ERROR: 529
Ask for registration on
UK Orange network
Selection failed – emer-
gency calls only
AT+COPS=0
OK
Register on home net-
work, succeeded
AT+COPS=3,0
OK
Set
alphanumeric
AT+COPS?
+COPS: 0,0,”Orange F”
Ask for current PLMN,
OK
home PLMN is
France Telecom Orange
AT+COPS=2 OK
Request
deregistration
from network, OK
AT+COPS?
+COPS: 2
Ask for current PLMN
Note: ME is unregistered
until
selected.31
B A C K
- TR-36B (88 pages)
- TD-36 (44 pages)
- TR-36 (36 pages)
- TR-36B (20 pages)
- IDW-90 AT (97 pages)
- GD-01 (20 pages)
- MRI-128-F4G (175 pages)
- MRI-128-F4G (169 pages)
- GDW-11 485 (380 pages)
- GDW-11 (40 pages)
- Lynx Series (28 pages)
- ODW-720-F1 (20 pages)
- ODW-720-F1 (24 pages)
- ODW-720-F2 (36 pages)
- ODW-730-F2 (36 pages)
- ODW-730-F1 (24 pages)
- DDW-120 (24 pages)
- DDW-226-EX (24 pages)
- DDW-226-EX (24 pages)
- DR-270 (28 pages)
- DR Series (460 pages)
- ED-2x0 (20 pages)
- MRD-3x0 (199 pages)
- FD-80 (24 pages)
- FDV-206-1D-1S (24 pages)
- GD-01 US (24 pages)
- LD-01 (8 pages)
- IDW-90 (44 pages)
- Lynx-x10-F2G (16 pages)
- Lynx-x08-F2G-S2 (20 pages)
- MDI-110-F3x (16 pages)
- MR-2x0 (28 pages)
- ODW-642 (28 pages)
- PII PoE Injector (12 pages)
- Viper Series (977 pages)
- SDI-5xx (12 pages)
- RFI-xx (32 pages)
- SDI-8xx (16 pages)
- RFIR-xxx (24 pages)
- TD-29 (16 pages)
- SDW-5xx (24 pages)
- TD-23 (24 pages)
- TD-29P (16 pages)
- Viper 408 (20 pages)