6196-2220
+DS – V.42 bis data compression
Description:
This command enables or disables V.42bis data compression if this feature is supported
on the product.
Syntax:
AT+DS=
Command example
Possible responses
Note
AT+DS=? +DS: (0-3),(0,1),
Test
command
(512-4096),(6-250)
OK
AT+DS=3,0,4096,250
OK
Set new parameters
AT+DS?
+DS: 3,0,4096,20
Current values
OK
Defined values:
Four numeric sub-parameters are accepted:
specifies the desired direction(s) of operation of the data compression function; from the
DTE point of view, (default is 3).
0:
Negotiated ... no compression
1:
Transmit only
2:
Receive only
3:
Both directions, accept any direction
specifies whether or not the DCE should continue to operate if the desired result is not
obtained, (default is 0),
0:
Do not disconnect if V.42 bis is not negotiated by the remote DCE as
specified in
1:
Disconnect if V.42 bis is not negotiated by the remote DCE as specified in
512-4096:
specifies the maximum number of dictionary entries that should be
negotiated, (default is 4096).
6-250:
specifies the maximum string length to be negotiated, (default is 250).
B A C K