Westermo GD-01 User Manual
Page 138

138
6196-2220
+WCCS – Custom Character Set
Description:
This command allows to edit and display the custom character set tables.
The “CUSTOM” mode of +CSCS and the +WPCS commands use this character set.
In this mode, when the user enters a string, this string is converted into GSM alphabet
using the Custom To GSM table. In a similar way, when the user requests a string
display, the string is converted from GSM alphabet using the GSM To Custom table.
In edition mode, the edition session is terminated by
Only hexadecimal characters (‘0’...’9’, ‘A’...’F’) can be used.The number of characters
entered must equal the edition range requested, otherwise the command will terminate
with a “+CME ERROR: 3” result.
Syntax:
AT+WCCS=