132
6196-2220
+WDWL – Downloading
Description:
This command switches the product to download mode. Downloading is performed
using the 1K-XMODEM protocol.
Syntax:
AT+WDWL
Command example
Possible responses
Note
AT+WDWL
+WDWL: 0
Switch on downloading
mode, start the down-
loading
...Downloading in
progress
AT+CFUN=1
OK
Reset the product
at the end
+WDR – Data Rate
Description:
This command allows the data rate for bearer data to be configured
(available for outgoing calls only).
Syntax:
AT+WDR=
Command example
Possible responses
Note
AT+WDR=
AT+WDR=?
+WDR: (0-2)
Possible values, Half Rate
available.
AT+WDR?
+WDR:
Request current value
AT+WDR=1
OK
Configure voice type
FR,HR with HR prefered.
Bearer is configured
AT+WDR=3 +CME
ERROR: 3
Syntax
error
AT+WDR?
+WDR: 1
Ask the current value
OK
Defined values:
Data coding type.
0:
FR
1:
FR, HR with HR preferred
2:
HR, FR with FR preferred.
B A C K
- TR-36B (88 pages)
- TD-36 (44 pages)
- TR-36 (36 pages)
- TR-36B (20 pages)
- IDW-90 AT (97 pages)
- GD-01 (20 pages)
- MRI-128-F4G (169 pages)
- MRI-128-F4G (175 pages)
- GDW-11 485 (380 pages)
- GDW-11 (40 pages)
- Lynx Series (28 pages)
- ODW-720-F2 (36 pages)
- ODW-720-F1 (20 pages)
- ODW-720-F1 (24 pages)
- ODW-730-F2 (36 pages)
- ODW-730-F1 (24 pages)
- DDW-120 (24 pages)
- DDW-226-EX (24 pages)
- DDW-226-EX (24 pages)
- DR-270 (28 pages)
- DR Series (460 pages)
- ED-2x0 (20 pages)
- MRD-3x0 (199 pages)
- FD-80 (24 pages)
- FDV-206-1D-1S (24 pages)
- GD-01 US (24 pages)
- LD-01 (8 pages)
- IDW-90 (44 pages)
- Lynx-x10-F2G (16 pages)
- Lynx-x08-F2G-S2 (20 pages)
- MDI-110-F3x (16 pages)
- MR-2x0 (28 pages)
- ODW-642 (28 pages)
- PII PoE Injector (12 pages)
- Viper Series (977 pages)
- SDI-5xx (12 pages)
- RFI-xx (32 pages)
- SDI-8xx (16 pages)
- RFIR-xxx (24 pages)
- TD-29 (16 pages)
- SDW-5xx (24 pages)
- TD-23 (24 pages)
- TD-29P (16 pages)
- Viper 408 (20 pages)