background image

Operating Instructions

UPC-166 Function Submenu List and Descriptions

Table 3-2

UPC-166 Function Submenu List

continued

3-39

UPC-166-OM
(V4.0)

(continued)

• Loss of Input Signal Selection

In the event of input video Loss of Signal (LOS), determines action to be
taken as follows:

Disable Outputs: Disable all outputs.
Freeze Last Frame: Freeze image to last good frame (for SDI, last

frame having valid SAV and EAV codes; for analog, last frame free
of timing errors).

Freeze to Color: Freeze image to a color raster (as selected using

Framesync LOS Freeze Color control).

• Framesync LOS Freeze Color

In the event of LOS with Freeze to Color enabled above, sets the image
raster color from choices shown to the left.

• Custom Color Hue

Adjusts raster hue (phase angle) for custom LOS color.

(-360° to 360° range in 0.1° steps; null = 0°)

• Custom Color Saturation

Adjusts raster saturation level for custom LOS color.

(0% to 100% range in 0.1% steps)

• Custom Color Y Level

Adjusts raster luma level for custom LOS color.

(64 to 940 range)

• Reset Framesync

Resets the frame sync, clearing any buffered audio and video.

When Confirm is clicked, a Confirm? pop-up appears, requesting
confirmation.

• Click Yes to reset the frame sync.
• Click No to reject reset.