beautypg.com

Comtech EF Data SDM-2020 User Manual

Page 88

background image

SDM-2020 Satellite Demodulator

Revision 4

Front Panel Operation

MN/SDM2020D.IOM

6–24

Function Select: Monitor: Corrected BER

CORRECTED BER

4.0 E-3


Displays the current corrected BER estimated or No Data (if carrier is not locked).

Range: m.m E-e.

Notes:

1. Low limit based on modulation and coding selection.
2. High limit is 1.0 E-12.

Press [

←] or [→] to move the flashing cursor, and [↑] or [↓] to increment or decrement

the selected kbps. Press to execute the change.

Function Select: Monitor: Eb/No

EB/NO

16.0 dB

Displays the current Eb/N0 estimated or No Data (if carrier is not locked).

Range: mm.m.

Notes:

1. Low limit based on modulation and coding selection.
2. High limit is 16.0 dB.


Press [

←] or [→] to move the flashing cursor, and [↑] or [↓] to increment or decrement

the selected kbps. Press to execute the change.