Initial defaults, 13 initial defaults – Comtech EF Data SDM-2020 User Manual
Page 122
SDM-2020 Satellite Demodulator
Revision 4
Front Panel Operation
MN/SDM2020D.IOM
6–58
UTILITY
FACTORY SET-UP
CAUTION
This configuration is used for factory alignment and filter setup parameters.
To avoid demodulator failure, Factory Setup should not be changed by
unauthorized persons.
6.1.13 Initial
Defaults
Initial default settings for the demodulator are listed in Table 6-4.
Table 6-4. Initial Defaults
Configuration Demodulator
Demodulation/Code Rate
(see Note 1)
QPSK 1/2
Energy Dispersal
On
Data Rate
(see Note 1)
15.000000 Mbps
RS Decoder
Corr On
Symbol Rate
(see Note 1)
16.276596 Msps
BER Threshold
None
Demodulation/Code Rate
(see Note 2)
QPSK 3/4
E
b
/N
0
Threshold
None
Data Rate
(see Note 2)
44.736000
Mbps
E
b
/N
0
THRESH ALM
Off
Symbol Rate
(see Note 2)
32.362213 Msps
Sweep Range
100000 Hz
RX IF Frequency
(see Note 3)
1200 MHz
Reacquisition
0 seconds
RX IF Frequency
(see Note 4)
70 MHz
RF Input Select
1
LNB Power
Off
Configuration Interface
RX Clock Phase
(see Note 1)
Normal
EXT-REF Freq
1544 kHz
(see Note 2)
RX Data Phase
Normal
TX TERR CLK Freq
44736 kbps
(see Note 2)
RX Data Fault
None
TX Coding Format
AMI
(see Note 2)
DVB Framing Type
188
Buffer Clock
RX (Satellite)
(see Note 2)
RX 2047 Pattern
Off
RX Coding Format
AMI
(see Note 2)
INTF Loopback
see Note 2)
Off
Buffer Size
12 ms
(see Note 2)
Monitor
Raw BER
2.4 E-3
DEMOD Spectrum
Normal
Corrected BER
4.0 E-3
LNB Current
0 mA
Eb/N0
16.0 dB
2047 Pattern
No Data
Eb/N0 Margin
10.0 dBm
Buffer Fill
50%
Receive Signal
-45.0 dBm
2047 Errors
No Data
Sweep Frequency
+0 Hz
Utility Demodulator
Demodulator Type
DVB
Table 6-4. Initial Defaults (Continued)