SDM-2020 Satellite Demodulator

Revision 4

ECL/HSSI Data Interface

MN/SDM2020D.IOM

10–11

Use the timing diagram shown in Figure 10-8 for the worst case interface timing
specifications.

CLOCK

DATA

tsu

th

tw

T

SYNC

DVALID

Figure 10-8. Interface Timing


The timing parameters for the serial data transmit interface are listed in Table 10-7.

Table 10-7. Transmit Timing Parameters

Parameter

Description

Min

Max

Units

f

Operating frequency (1/T)

1.5

100

MHz

T

Clock period (1/f)

10

666

nsec

t

w

Clock

pulse

width

4

-

nsec

t

su

Setup time, DATA or SYNC to CLOCK

3

-

nsec

t

h

Hold time, CLOCK to DATA or SYNC invalid

3

-

Nsec



The timing parameters for the serial data receive interface are listed in Table 10-8.

Table 10-8. Receive Timing Parameters

Parameter

Description

Min

Max

Units

f

Operating frequency (1/T)

1.5

100

MHz

T

Clock period (T)

10

666

nsec

t

w

Clock

pulse

width

4

-

nsec

t

su

Setup time, DATA, DVALID, or SYNC to CLOCK

3

-

nsec

t

h

Hold time, CLOCK to DATA, DVALID or SYNC
invalid

3 - nsec