Front Panel Operation

MN/SDM2020D.IOM

6–53

IMPORTANT

L-Band only.


Set up menu for Low current thresholds.

Range:

0 to 1000 mA.

1. Press [ENTER] once to access change mode.
2. Press

[

↑] or [↓] to alternate between the Low and Hi LNB current thresholds.

3. Press

[

→] to move the cursor to the appropriate decimal position and use the [↑]

or [

↓] to change value.

4. Pressing [ENTER] will program the displayed the value.

Function Select: Utility: System: LNB CURR LIMIT LO

(Conditional)

LNB CURR LIMIT

LO = 0 mA

IMPORTANT

L-Band only.

Set up menu for Hi current thresholds.

Range:

0 to 1000 mA.

1. Press [ENTER] once to access change mode.
2. Press

[

↑] or [↓] to alternate between the Low and Hi LNB current thresholds.

3. Press

[

→] to move the cursor to the appropriate decimal position and use the

[

↑] or [↓] to change value.

4. Pressing [ENTER] will program the displayed the value.


Note: The Hi current value shall be > the Low current value.

Function Select: Utility: System: LNB Voltage (Conditional)

LNB VOLTAGE

13 VDC


Status Only.