beautypg.com

Description of data interfaces, 4 description of data interface, 1 interface/m&c software requirements – Comtech EF Data SDM-2020 User Manual

Page 31

background image

SDM-2020 Satellite Demodulator

Revision 4

Introduction

MN/SDM2020D.IOM

1–5

1.4

Description of Data Interface

Table 1-2 provides a list of the data interface available. Each data interface is a plug-in
module that provides a specific terrestrial connection to the demodulator unit. Where
practical, both the TX (modulator) and RX (demodulator) paths are incorporated into the
data interface. Refer to the applicable chapter for description of the interface module.

Table 1-2. Comtech EF Data Part Numbers for Data Interface Modules

Part Number

Description

PL/5805

RS422 Serial/Parallel Data Interface

PL/5806-3

RX only ECL/HSSI Serial Data Interface

PL/5807

ASI/RS422 (Asynchronous Serial Interface/Serial Data Interface

PL/5814

LVDS-DVB Serial/Parallel Data Interface

PL/6168-1

G.703 Data Interface

PL/6175-2

SMPTE 310M Data Interface

PL/8160

ASI/LVDS Interface


The 70/140 MHz IF interface is a plug-in card designed to replace the current L-Band
demodulator RF. It will be plug compatible both physically and electrically with the
current L-Band demodulator. The demodulator board is designed to require minimal
changes to the current SDM-2020 firmware and mechanical assemblies.

1.4.1

Interface/M&C Software Requirements

Note: This section does not apply to SDM-2020 Demodulator incorporating PCB,
AS/7733.

As additional data interfaces are introduced, the software is revised to support the
operation of each interface. Table 1-3 summarizes the minimum software version
necessary to operate each interface type.

Table 1-3. Minimum Software Revisions

Data Interface

Specification P/N

Minimum Software Version

RS-422 SP/5805 1.1.1
LVDS SP/5814 1.1.1
ASI/RS-422 SP/5807

1.1.1

ECL/HSSI SP/5806-1/-2

1.1.2

G.703 SP/6168 2.2.1
SMPTE 310M

SP/6175-1

2.2.4

ASI/LVDS SP/8160

4.3.3

CAUTION

To avoid damaging the Demodulator, always disconnect the power before
removing or installing a data interface.