beautypg.com

Remote control commands, Appendix a. remote control commands – Comtech EF Data SDM-2020 User Manual

Page 201

background image

A–1

Appendix A. REMOTE CONTROL

COMMANDS

This appendix describes the remote control operation of the demodulator.

A.1 General

Firmware number:

FW/6224-1V Software Version: 6.4.2

FW/7334-1C Software Version: 22.2.1

Remote controls and status information are transferred via an EIA-485 (optional EIA-232)
serial communications link.

Commands and data are transferred on the remote control communications link as
US ASCII-encoded character strings.

The remote communications link is operated in a half-duplex mode.

A remote controller or terminal initiates communications on the remote link. The
demodulator never transmits data on the link, unless it is commanded to do so.

A.1.1 Message

Structure

The ASCII character format used requires 11 bits/character:

• 1 start bit
• 1 parity bit (Not applicable to 8 information bit setup)
• 2 stop bits
• 7 information bits or 8 information bits with no parity bit

Messages on the remote link are commands and responses.