3–8

3.2.6 Fuse

Data

Fuse Type

Littlefuse 215002 5 x 20 mm

Fuse T2A

H250V

Time Delay, 2A, High Breaking Capacity
Double Pole
(Approved to IEC 127, Sheet V and Underwriters Laboratories)


To replace a fuse, proceed as follows:

1. Remove the fuseholder on the back of the IEC 320 style A/C input connector .

2. Replace fuse with same or equivalent rated part and/or model number.

Refer to Input Power requirements as specified in Chapter 1, 1-6.

3.2.7

DC Power (Optional)

DC power is an available option. Contact Comtech EF Data Customer Support for further
assistance.

3.2.8

Ground (GND) or Earth

A #10-32 stud is available on the rear panel for the purpose of connecting a common chassis
ground among all of the equipment.

Note: A safety ground is provided through the AC power connector.