beautypg.com

A.1.12 error performance status – Comtech EF Data SDM-2020 User Manual

Page 218

background image

SDM-2020 Satellite Demodulator

Revision 4

Remote Control Commands

MN/SDM2020D.IOM

A–18

A.1.12

Error Performance Status

Raw BER

Command:
Response:

>add/RBER_xm.mE-ee'cr''lf']

Where:

x = < or > (data modifier to indicate that the error rate
is less than or greater than the returned value).

m.m = 1.0 to 9.9 (error rate mantissa).

ee = 1 to 99 (error rate exponent).


Notes:

1. The 'x' (< or >) parameter is only returned if the

error rate has exceeded the computational
resolution of the system.

2. 'No Data' is returned if the error rate cannot be

calculated.

3. 'Sampling' is returned if not enough data is

currently available to calculate the error rate.

Corrected
BER

Command:
Response:

>add/CBER_xm.mE-ee'cr''lf']

Where:

x = < or > (data modifier to indicate that the error rate
is less than or greater than the returned value).

m.m = 1.0 to 9.9 (error rate mantissa).

ee = 1 to 99 (error rate exponent).


Notes:

1. The 'x' (< or >) parameter is only returned if the

error rate has exceeded the computational
resolution of the system.

2. 'No Data' is returned if the error rate cannot be

calculated.

3. 'Sampling' is returned if not enough data is

currently available to calculate the error rate.

Interface
Read Error
Status (RX
2047
Pattern
Status)

Command:
Response:

>add/IRES_tttt_xn.nE-ee’cr’’If’]

Where:

tttt = 2047 (indicates type of error being read).

< or > (data modifier to indicate that the error rate is
less than or greater than the returned value).

n.n = 1.0 to 9.9 (error rate mantissa).

ee = 1 to 99 (error rate exponent).


Notes:

1.

The x (< or >) parameter is only returned if the
error rate has exceeded the computational
resolution of the system.

2.

“No Data” is returned if the error rate cannot be
calculated.

3.

“Sampling” is returned if not enough data is
currently available to calculate the error rate.

This command returns the 2047 error rate (only available

when G.703 interface is installed. The IRE_command is
used to enable or disable the reading of the 2047 error. If
an interface other than G.703 is used, refer to the Non-
G.703 section.